Pilot Is Lit but the Gas Fireplace Burner Won’t Start: What That Usually Means
A gas fireplace pilot can stay lit while the main burner still refuses to start. The cause may be in the switch circuit, millivolt output, flame-sensing, control module or gas valve, and the right diagnosis depends on the fireplace design.

A pilot flame and a main burner are different parts of the sequence
If the pilot stays lit but the main burner does not start, the fireplace has already completed one part of the operating sequence. The remaining problem may involve the wall switch or remote circuit, millivolt output, flame-sensing, control module, wiring, gas valve or another safety-related condition.
Millivolt fireplaces depend on the pilot assembly for electrical power
Many standing-pilot fireplaces use a thermopile to generate a small electrical signal that operates the main gas valve through the switch circuit. A pilot can stay lit even when the available voltage under load is not sufficient to open the main valve. Open-circuit voltage alone does not prove the system will operate correctly under load.
Electronic ignition fireplaces diagnose differently
Intermittent-pilot and electronic ignition systems use powered controls, flame-sensing and ignition logic rather than relying only on a millivolt circuit. Battery backup, control-module status, remote pairing and flame-sensing conditions can all affect whether the main burner is allowed to open.
The wall switch or remote can still be the problem
Loose switch wiring, a failed wall switch, remote receiver, thermostat contact or connector can interrupt the call for the main burner. A technician can determine whether the control signal is reaching the gas valve or control module without replacing parts by guess.
Do not jump the gas valve or defeat safety controls
Gas-valve terminals and safety circuits should not be bypassed as a homeowner troubleshooting step. Incorrect testing can damage controls or create an unsafe condition. Gas pressure, valve operation and flame-safety components require the correct service procedures for the exact fireplace.
When the pilot itself also looks wrong
A weak, unstable or incorrectly positioned pilot flame can affect both flame proving and thermopile or thermocouple heating. Pilot contamination, gas-supply conditions or a failing pilot assembly may be involved, but the correct repair depends on the fireplace design and test results.